Protection Box Technical characteristics Protection Box 1 1 Tel@ 5 5 Tel 5 Tel@+TV 8 Tel@+TV Nominal Rating (A/W)* 16 A / 3680 W 16 A / 3680 W 10 A / 2300 W 10 A / 2300 W 10 A / 2300 W 10 A / 2300 W Voltage/Frequency 220V – 250V / 50/60Hz IEC 61643-1 PLC compatibility - - Surge test conditions Surge test conditions for IEC 61643-1 with 8/20µs pulse Uoc = 6,6 kV Up = 1,5 kV In = 2,5 kA Imax = 8 kA Protective devices Total rating 30 000 A 3 x MOV 10 000 A Response time <1ns Total power absorbed 1 110 Joules EMI/RFI filter 52dB from 100kHz to 100MHz - - Telephone and audio/video line protection RJ11/RJ45 telephone including broadband - 10 000 A - 10 000 A 10 000 A 10 000 A Audio/Video line - - - - 10 000 A 10 000 A Marking and standards Safety IEC 60-950, NFC 61-303 EMC EN 55082-2, EN 55022 class B, EN 61000-4-4 level 4 IEC 61000-4-5 10kV Surge protection IEC 61 643-1 Dimensions and weight Dimensions H x W x D(mm) 70 x 105 x 67 70 x 105 x 67 65 x 255 x 120 65 x 260 x 120 65 x 260 x 120 65 x 315 x 150 Net weight 0,160 kg 0,210 kg 0,610 kg 0,770 kg 0,840 kg 0,850 kg* Calculated for a nominal voltage at 230V Part Number Protection Box 1 1 Tel@ 5 5 Tel@ 5 tel@+TV 8 Tel@+TV French Sockets 66706 66707 66710 66711 66934 66935 Schuko" sockets 66708 66709 66712 66713 66936 66937 FR & B sockets - - 66932 66933 66938 -